The DSW 590 Series of Shakers are matched with the DSA 200K and DSA 240K Series of Power Amplifiers. Its armature supply is assembled in three 19-inch network racks of 36 unit height and field supply is assembled in two 19-inch network racks of 36 unit height. The water cooling system is assembled in two 19-inch network racks of 36 unit height. All three system communicate with each other over a galvanically isolated RS 485 interface.
Standard Features
- Complies with Machinery Directives, Low Voltage Directive and Electromagnetic Compatibility Directive under CE
- Aluminium or Magnesium alloy armature structure
- Hydrostatic central guidance bearing
- Trunnion mounted shaker for operation in vertical and horizontal position
- Pneumatic and DC based auto-centring of armature head
- Body isolation using air bellows to isolate vibrations from the shaker
- Air isolation mounts between system base and ground
- Lowering of gauss level at the armature head
- Hermetically sealed construction
Optional Features
- Up to 76 mm (3.0 in) with Long Stroke
- PC based Power Amplifier Remote
- Auto Resume from power failure
- Auto Stop after user profile completion
- Attachment to Horizontal Slip Table and Head Expander
- Integration with Environmental Chamber
Technical Specifications
SEW 590 Series Shaker, DSA Series Amplifier |
DSW 590 – DSA 200K |
DSW 590 – DSA 240K |
System Performance |
Armature Diameter |
590 mm |
590 mm |
Sine Force (peak) |
12000 kgf (26400 lbf, 120 kN) |
16000 kgf (35200 lbf, 160 kN) |
Random Force (rms) |
12000 kgf (26400 lbf, 120 kN) |
16000 kgf (35200 lbf, 160 kN) |
Shock Force (rms) |
24000 kgf (52800 lbf, 240 kN) |
32000 kgf (70550 lbf, 320 kN) |
Acceleration (sine) |
85 g |
100 g |
Velocity (sine peak) |
2.0 m/s |
2.0 m/s |
Velocity (shock peak)* |
3.7 m/s |
3.7 m/s |
Displacement (pk-pk)** |
51 mm (2 in) / 76 mm (3 in) |
51 mm (2 in) / 76 mm (3 in) |
Axial Resonance (±5%) |
1700 Hz |
1700 Hz |
Useful Frequency Range |
5 to 2000 Hz |
5 to 2000 Hz |
Protection Interlocks |
Mains Input Over & Under Voltage, Over Current, Loss of Input Phase, Over Temperature Amplifier & Shaker, Field Fail, Cooling, User Safety Interlock if specifically required by the customer |
Shaker Characteristics |
Moving Element Mass |
160 kg |
160 kg |
Internal Load Capability |
2000 kg |
2000 kg |
Suspension Axial Stiffness |
10 kg/mm |
10 kg/mm |
Suspension Cross-Axial Stiffness |
3200 kg/mm |
3200 kg/mm |
Stray Magnetic Field*** |
< 1 mT (10 gauss) |
< 1 mT (10 gauss) |
Compressed Air**** |
7 bar (100 psi) |
7 bar (100 psi) |
Cooling |
A dedicated cooling system for storing, circulating and cooling distilled water used for cooling |
Amplifier Characteristics |
Power Output |
200 kVA |
240 kVA |
Total Harmonic Distortion***** |
Typically 0.5% |
Typically 0.5% |
Input Impedance |
> 10 kΩ |
> 10 kΩ |
Input Sensitivity |
4 Vrms, Compatible with all standard controllers |
4 Vrms, Compatible with all standard controllers |
Signal-to-Noise Ratio |
> 75 dB |
> 75 dB |
Power Efficiency***** |
> 92% |
> 92% |
Armature Insert Pattern |
SEW 590 Shaker |
Pattern |
PCD |
PCD |
PCD |
PCD |
Position of Insert |
Centre |
200 mm |
400 mm |
550 mm |
No. of Inserts (Total – 25) |
1 |
8 |
8 |
8 |
Safety Norms |
CE |